KMC Controls - KMC BACnet  

BACnet Building Controller

Primary Control Unit
BAC-A1616BC
Date Last Saved: 7/27/2010 1:26:07 PM

Product Name(s): BACnet Building Controller
Product Description: The BAC-A1616BC Controller can be used to consolidate the control of central mechanical plants and air handling units, or as part of a complete building automation system. Controller has built in Webserver.
Product Application(s):
Point Quantity Characteristics
Analog Input (AI): N.A.
Digital Input (DI): N.A.
Universal Input (AI or DI): 16 Pulse Counting
0-12 VDC
4-20 mA
Thermistor
Analog Output (AO): N.A.
Digital Output (DO): N.A.
Universal Output (UO):
Other:
A/D Converter Resolution
8 bit
10 bit
12 bit
16 bit
Other
D/A Converter Resolution
6 bit
8 bit
10 bit
No Analog Output
Other 12 bit
HOA switches provided on each output?
Note: These are also available as an add-on from 3rd party vendors.
No
Both AO and DO
DO Only
Other
Indicating status LED on each output?
No
AO and DO
AO Only
DO Only
Other
Integral Flow Sensor? No
Integral Damper Actuator? No
Can controller accept occupant override from thermostat? N.A.
Can controller accept occupancy sensor input? N.A.
Expander Boards Up to 7 CAN-A168EIO expansion modules can be added. Can be installed up to 200 feet from the BAC-A1616BC controller.
Expansion Device Model #AIDIUIDOAOUOOther
CAN-A168EIO 16 8
Network Ports, Protocol(s), and Speed(s) Supported
(Note: See 'Architecture' for network details)
(1) 10/100baseT ethernet port
(2) EIA-485 ports for BACnet MS/TP @ up to 76.8 kbps
External Communication Ports, Speeds and Access Devices (1) Serial bus connection for daisy-chaining I/O expansion modules
(1) USB 2.0 port with type A connector
Additional Information (Optional)
Network Accessing Capabilities via Controller
Access controller only
Access controller plus additional controllers on network segment / LAN
Access all controllers on system
No access available on this controller
Other
Controller Access Devices
Laptop/PC
Local Display Panel (controller-mounted)
Local Display Panel (zone-mounted)
Handheld Interface Device (proprietary device)
PDA (3rd-Party HID)
Zone-Based port (details below)
Other Internet accessible
Zone-Based Interface Access
Zone Interface Hardware
Zone-Mounted touchpad (thermostat or stand-alone display)
HID (proprietary device)
PDA (3rd party HID, with software)
Laptop/PC
none
Other
*Note: This section covers the capabilities for accessing the controller or other parts of the network from the controller (i.e. 'bottom-up').
Standard access functionality is covered in the Architecture and Software sections.
**Does NOT include front-end OI functions. See vendor for specific functions available.
Functions Available Through Field Interface**:View ParamsChange ParamsChange
Programs/Logic
O&M SupportTAB/Cx Support
Laptop/PC
Local Display Panel (controller-mounted)
Local Display Panel (zone-mounted)
Handheld Interface Device (proprietary device)
PDA (3rd-Party HID)
Zone-Based port (details below)
Other Internet accessible
Microprocessor(s) 32 bit
Clock Type
Powered, battery-backed
Battery powered
Powered, no battery backing
None
Other
Clock Synchronization Information not provided
Volatile Memory (RAM) Capacity Up to 256 MB SDRAM
Volatile Memory (RAM) Uses
RAM use unrestricted
RAM use restricted as shown below
Information Not Provided
Program Execution / Calculation storage
Data / Trends / Alarms storage
Configuration / Parameter storage
Control Programming storage
Others
Is Volatile Memory Supported By Battery? Information not provided.
Battery Type(s) Information not provided.
Battery Life Information not provided.
Backup Battery Operating Time 72 hours
Non-Volatile Memory Capacity (EEPROM/Flash)* 64 MB flash
Non-Volatile Memory Uses
Data / Trends / Alarms / Calculation Storage
Configuration / Parameter Storage
Control Programming Storage
Controller Operating System
Other
Additional Information
* Items in NV memory are not lost upon power or battery failure. Other types of NV memory such as EPROM, NOVROM, etc. do not directly impact system performance.
Can trend data be stored in this controller? Yes.
How many total trend values can be stored? 64 default objects and up to 256 objects. Each object holds up to 256 samples.
What is the controllers role in trending? Information not provided.
Can controller be programmed to 'push' data to archive or are trends 'pulled' from controller?
When full, does controller automatically send up trend data, overwrite data, or stop logging data? Information not provided.
Programming Method(s) Information not provided
Resident vs Non-Resident Program Execution Resident
Scheduling
Resident/Supervisory. This controller supervises the scheduling of other controllers.
Resident/Stand Alone. This controller contains its own schedule. 10 - 100 scheduling objects
Non-Resident. This controller is dependent upon another controller for its schedule.
None. This controller has no scheduling features.
Other
Resident Energy Management
Energy management algorithms for this controller can be custom programmed
Pre-programmed/built-in algorithms available, and are fully editable using custom programming
Pre-Programmed/built-in with limited editing via template-based programming
Controller is not typically used for energy management functions
Others Information not provided.
Specific Pre-Programmed Algorithms Available
None (custom programming only)
None (not applicable)
Optimal Start/Optimal Stop
Peak Demand Limiting/Load Shedding
Economizer (enthalpy, dry-bulb, CO2, modulating/2-position, etc.)
Other Information not provided.
Additional Energy Management functions are resident at SI
Additional Programming Functions
DDC Loops (P, PI, PID) PID
Automatic PID Tuning Feature Information not provided.
Automatical-Dial Alarm Support Information not provided.
Does controller perform multiple retries and buffer/store alarm until connection is made? Information not provided.
Are multiple destinations possible? Information not provided.
Upon controller power loss or hardware failure:
Are network communications affected? Information not provided.
Is loss recognized on/by the network and alarm reported? Information not provided.
DO and AO response?
Outputs fail to a user pre-specified position
Outputs fail to a normal (unpowered) position
Outputs fail to last position
Other Information not provided.
Volatile memory functions?
Lost
Retained for life of backup battery
Other RAM automatically backed up to flash memory when signaled by the UPS shutdown (future upgrade)
Upon restoration of power does the controller:
Auto-reboot without operator intervention? Yes. Only with future upgrade of uniteruptable power supply.
Automatically reset/synchronize the clock? Yes. Only with future upgrade of uniteruptable power supply.
Update all monitored functions? Information not provided.
Generate an alarm if backup battery is dead? Information not provided.
Upon network or communications failure does controller:
Continue to operate standalone? Information not provided.
Operate with last global settings or user-specified value? N.A.
Do broken network segments continue to communicate within the remaining segment?
(Note: May depend on proper termination of segments for higher speed networks.)
Information not provided.
Does network automatically reconfigure upon restoration? Information not provided.
Does network store 'loss of communications' alarm with time of event? Information not provided.
Additional Information (optional)
Self Test Diagnostics
Does controller have internal self-test diagnostics to check:
Processor failure? Information not provided.
Internal hardware failure? Information not provided.
Open/shortened sensor? Information not provided.
Others?
 
Control Enclosure Optional
Power Supply Required
Voltage 24 VAC
VA 35 VA @ 28.8 VAC
Surge Protection 1.6 A Fuse
Underwriters Laboratories UL 916 Energy Management Equipment
FCC FCC Class A, Part 15, Subpart B
CE
LonMark Certified
Yes
No
No - but LonWorks compatible
Information not provided
BACnet (BTL) Certified
Yes
No
Not submitted for testing
Information not provided
Other